LF型噴淋管 LF model spray pipe

LF型噴淋管 LF model spray pipe

產(chǎn)品編號
描述

1、總述

 

  LF型噴淋管是空調(diào)系統(tǒng)中作為加濕或去濕的主要部件。

 

  噴淋管采用中進(jìn)水或下進(jìn)水結(jié)構(gòu),主管采用鍍鋅無縫鋼管或不銹鋼管,支管采用PVC-U工程塑料管,主管和支管之間采用螺紋聯(lián)接,便于更換或檢修。

 

  噴嘴為ABS工程塑料,不銹鋼卡子連接或螺紋連接,具有重量輕,安裝方便、穩(wěn)定牢固,便于檢修、經(jīng)久耐用、永不生銹等優(yōu)點(diǎn)。規(guī)格有Φ3mm~Φ8mm。

 

As a major part for humidification or dehumidification in air conditioning system, main pipe is made of galvanized seamless steel tube or stainless steel tube, while branch pipe is made of PVC-U engineering plastic. Threaded connection is applied for main and branch pipe linking,which ensures convenient component exchange and maintenance.

 

Nozzle is made of ABS engineering plastic with stainless steel clip or threaded connection. It has such advantages as light weight, easy installation, stable, convenient maintenance, structural durability and guarantee against rust. Available specifications: Φ3mm~Φ8mm.

 

2、型號 Type

 

LFP-B×H –Φ (Φ為噴嘴直徑 Diameter of Nozzle mouth)

 

3、常用規(guī)格 Standard Specification

 

LFP-B×H-Φ4 (H=3400,支管斷料Branches 1500) 根據(jù)設(shè)計圖紙制作 Custom-made according to Prints

 

4、主要配置

 

  主管:不銹鋼無縫管/鍍鋅無縫管,支管:PUV塑料管,普通Φ4mm、Φ6mm卡式噴嘴,不銹鋼卡子。Φ6mm羅瓦噴嘴另行標(biāo)明,密度按Φ6mm普通卡式噴嘴布置

 

Main Configuration: Main pipe: Stainless Steel Seamless Pipe/Galvanizing Seamless Tube; Branch tube: PUV plastic tube, standard Φ4mm,Φ6mm clip nozzle; stainless steel clips. Φ6mm LUWA nozzle need to be indicated specifically, density as normal Φ6mm clip nozzles.

 

5、技術(shù)參數(shù):

 

  噴淋管中進(jìn)水。設(shè)噴淋室截面B×H,H=3200。

 

Specifications: Water enters through Spraying pipes. Spraying room section B×H,H=3200.

 

  噴淋管高度3200,支管間距450,中進(jìn)水,Φ4/6/8mm噴嘴,標(biāo)準(zhǔn)壓力0.25Mpa。

 

Height of Spraying pipes 3200, distance between branch pipes 450, middle position water entering, Φ4/6/8mm nozzles, standard pressure 0.25 MPa:

設(shè)計寬度
系列B

支管
數(shù)量

Φ4mm噴嘴

Φ6mm噴嘴

Φ8mm羅瓦噴嘴

主管
直徑

數(shù)量(只)

噴水量(t/h)

數(shù)量(只)

噴水量(t/h)

數(shù)量(只)

噴水量(t/h)

2200~2600

5排

110

23

110

36

80

64

Φ89

2800、3000

6排

132

28

132

44

96

77

Φ89

3200、3400

7排

154

32

154

51

112

90

Φ89

3600、3800

8排

176

37

176

58

128

102

Φ108

4000~4400

9排

198

42

198

65

144

115

Φ108

4600、4800

10排

220

46

220

73

160

128

Φ125

5000、5200

11排

242

51

242

80

176

140

Φ125

 

Designed
Breadth
B

Branch pipe quantity

Φ4mm Nozzle

Φ6mm Nozzle

Φ8mm Luwa Nozzle

Diameter of
Main pipe

Quantity
(piece)

Water volume
(t/h)

Quantity
(piece)

Water Volume
(t/h)

Quantity
(piece)

Water Volume
(t/h)

2200~2600

5 rows

110

23

110

36

80

64

Φ89

2800、3000

6 rows

132

28

132

44

96

77

Φ89

3200、3400

7 rows

154

32

154

51

112

90

Φ89

3600、3800

8 rows

176

37

176

58

128

102

Φ108

4000~4400

9 rows

198

42

198

65

144

115

Φ108

4600、4800

10 rows

220

46

220

73

160

128

Φ125

5000、5200

11 rows

242

51

242

80

176

140

Φ125

  寬度5000以上盡量分2段制作安裝(根據(jù)擋水板分段情況)

 

  噴淋管高度≤2000時,可以采用下進(jìn)水或上進(jìn)水方式。

 

  用于組合式空調(diào)機(jī)組時,可采用下進(jìn)水方式。

 

  下進(jìn)水,上進(jìn)水方式時,主管間距,噴嘴布置方式與中進(jìn)水方式相同。

 

Tubes breadth above 5000 should be separated in two sections (according to Water Eliminator sections).

 

When height of Spraying Pipes less than 2000, below water entering or up water entering is available;

 

When applied to Air Conditioning Units, below water entering is available;

 

For below water entering, up water entering, distances between main pipes and nozzle configurations should be the same as middle water entering.

 

6、外形簡圖及安裝要求

 

  主管上支管接頭焊接牢固,無虛焊。支管擰緊,端頭密封不漏水,噴嘴角度正確。

 

  主管兩端固定,無晃動,法蘭連接緊密,進(jìn)水管安裝順暢。外表做好防銹處理。

 

  每根主管安裝有壓力表、溫度計,調(diào)節(jié)閥門。

 

Outline Diagram and Set-up requirement:

 

Firm welding of branch pipe connectors to main pipes, no cold solder joint. Branch pipes tightened, no leakage at terminal seal. Nozzle angle correct.

 

Both ends of main pipes fixed, no waggle, tight connection of flanges; smooth set-up of water entering pipes. Rust preventive actions applied to surface.

 

Each main pipe should have manometer, thermometer, adjustment valve.

 

Φ4、Φ6mm噴嘴 間距125/250

 

梅花形布置,密度13~16只/平米

 

Φ4、Φ6mm nozzle, distance 125/250.

 

Quincunx disposition, density 13~16 pcs per square meter.

 

Φ8mm羅瓦噴嘴  間距180/360

 

梅花形布置,密度9.5~11.5只/平米

 

Φ8mm LUWA nozzle, distance 180/360,

 

Φ8mm LUWA nozzle, distance 180/360, 9.5~11.5

 

噴淋管安裝圖 Configuration of Spraying Pipes

 

 

7、檢驗(yàn)標(biāo)準(zhǔn):

 

  主管兩端固定,無晃動,法蘭連接緊密。

 

  進(jìn)水管安裝順暢,走向橫平豎直,并做好支撐。

 

  噴嘴無滴水,霧化效果好。

 

  管道上壓力表、溫度表、調(diào)節(jié)閥安裝正確,數(shù)據(jù)指示正確。

 

Inspection Criteria:

 

Both ends of main pipes fixed, no waggle, tight connection of flanges; smooth set-up of water entering pipes. Pipes should be straight forward, with good bracing.

 

No water dripping at the nozzles, good atomization effect.

 

Correct configuration of manometer, thermometer, adjustment valve, parameters indicate correctly.

 

圖一 LF噴淋排管外形及安裝尺寸圖

Sketch 3 Plan form and installation sketch of LF model spray pipe

 

1、噴淋主管 main spray pipe  2、支管 branch pipe  3、噴嘴 nozzle  4、支架 fixed mount  5、不銹鋼卡子 stainless clip

 

未找到相應(yīng)參數(shù)組,請于后臺屬性模板中添加

地址:江蘇省江陰市南閘街道東盟工業(yè)園東盟路11號

電話/Tel:0510-86283318   0510-86280616

郵箱/E-mail:sales@jygreenair.com

樣式不要動

發(fā)布時間:2022-03-31 11:46:14

Copyrignt ? 2022 江陰市格林艾爾環(huán)境科技有限公司     蘇ICP備16031300號-1     蘇公網(wǎng)安備 32028102000171號